1 /* 1 /*
2 * Copyright (c) 2013 The WebRTC project authors. All Rights Reserved. 2 * Copyright (c) 2013 The WebRTC project authors. All Rights Reserved.
3 * 3 *
4 * Use of this source code is governed by a BSD-style license 4 * Use of this source code is governed by a BSD-style license
5 * that can be found in the LICENSE file in the root of the source 5 * that can be found in the LICENSE file in the root of the source
6 * tree. An additional intellectual property rights grant can be found 6 * tree. An additional intellectual property rights grant can be found
7 * in the file PATENTS. All contributing project authors may 7 * in the file PATENTS. All contributing project authors may
8 * be found in the AUTHORS file in the root of the source tree. 8 * be found in the AUTHORS file in the root of the source tree.
9 */ 9 */
10 10
(...skipping 73 matching lines...) Expand 10 before | Expand all | Expand 10 after
84 #define BWE_TEST_LOGGING_LOG3(name, format, _1, _2, _3) 84 #define BWE_TEST_LOGGING_LOG3(name, format, _1, _2, _3)
85 #define BWE_TEST_LOGGING_LOG4(name, format, _1, _2, _3, _4) 85 #define BWE_TEST_LOGGING_LOG4(name, format, _1, _2, _3, _4)
86 #define BWE_TEST_LOGGING_LOG5(name, format, _1, _2, _3, _4, _5) 86 #define BWE_TEST_LOGGING_LOG5(name, format, _1, _2, _3, _4, _5)
87 87
88 // Print to stdout in tab-separated format suitable for plotting, e.g.: 88 // Print to stdout in tab-separated format suitable for plotting, e.g.:
89 // PLOT figure Context1_Context2_Name time value 89 // PLOT figure Context1_Context2_Name time value
90 // |figure| is a figure id. Different figures are plotted in different windows. 90 // |figure| is a figure id. Different figures are plotted in different windows.
91 // |name| is a char*, std::string or uint32_t to name the plotted value. 91 // |name| is a char*, std::string or uint32_t to name the plotted value.
92 // |time| is an int64_t time in ms, or -1 to inherit time from previous context. 92 // |time| is an int64_t time in ms, or -1 to inherit time from previous context.
93 // |value| is a double precision float to be plotted. 93 // |value| is a double precision float to be plotted.
94 // |ssrc| identifies the source of a stream
94 // |alg_name| is an optional argument, a string 95 // |alg_name| is an optional argument, a string
95 #define BWE_TEST_LOGGING_PLOT(figure, name, time, value) 96 #define BWE_TEST_LOGGING_PLOT(figure, name, time, value)
96 #define BWE_TEST_LOGGING_PLOT_WITH_NAME(figure, name, time, value, alg_name) 97 #define BWE_TEST_LOGGING_PLOT_WITH_NAME(figure, name, time, value, alg_name)
98 #define BWE_TEST_LOGGING_PLOT_WITH_SSRC(figure, name, time, value, ssrc)
99 #define BWE_TEST_LOGGING_PLOT_WITH_NAME_AND_SSRC(figure, name, time, value, \
100 ssrc, alg_name)
97 101
98 // Print to stdout in tab-separated format suitable for plotting, e.g.: 102 // Print to stdout in tab-separated format suitable for plotting, e.g.:
99 // BAR figure Context1_Context2_Name x_left width value 103 // BAR figure Context1_Context2_Name x_left width value
100 // |figure| is a figure id. Different figures are plotted in different windows. 104 // |figure| is a figure id. Different figures are plotted in different windows.
101 // |name| is a char*, std::string or uint32_t to name the plotted value. 105 // |name| is a char*, std::string or uint32_t to name the plotted value.
102 // |value| is a double precision float to be plotted. 106 // |value| is a double precision float to be plotted.
103 // |ylow| and |yhigh| are double precision float for the error line. 107 // |ylow| and |yhigh| are double precision float for the error line.
104 // |title| is a string and refers to the error label. 108 // |title| is a string and refers to the error label.
105 // |ymax| is a double precision float for the limit horizontal line. 109 // |ymax| is a double precision float for the limit horizontal line.
106 // |limit_title| is a string and refers to the limit label. 110 // |limit_title| is a string and refers to the limit label.
(...skipping 80 matching lines...) Expand 10 before | Expand all | Expand 10 after
187 } while (0) 191 } while (0)
188 192
189 #define BWE_TEST_LOGGING_PLOT_WITH_NAME(figure, name, time, value, alg_name) \ 193 #define BWE_TEST_LOGGING_PLOT_WITH_NAME(figure, name, time, value, alg_name) \
190 do { \ 194 do { \
191 __BWE_TEST_LOGGING_CONTEXT_DECLARE(__bwe_log_, __PLOT__, name, \ 195 __BWE_TEST_LOGGING_CONTEXT_DECLARE(__bwe_log_, __PLOT__, name, \
192 static_cast<int64_t>(time), true); \ 196 static_cast<int64_t>(time), true); \
193 webrtc::testing::bwe::Logging::GetInstance()->Plot(figure, value, \ 197 webrtc::testing::bwe::Logging::GetInstance()->Plot(figure, value, \
194 alg_name); \ 198 alg_name); \
195 } while (0) 199 } while (0)
196 200
201 #define BWE_TEST_LOGGING_PLOT_WITH_SSRC(figure, name, time, value, ssrc) \
202 do { \
203 __BWE_TEST_LOGGING_CONTEXT_DECLARE(__bwe_log_, __PLOT__, name, \
204 static_cast<int64_t>(time), true); \
205 webrtc::testing::bwe::Logging::GetInstance()->Plot(figure, value, ssrc); \
206 } while (0)
207
208 #define BWE_TEST_LOGGING_PLOT_WITH_NAME_AND_SSRC(figure, name, time, value, \
209 ssrc, alg_name) \
210 do { \
211 __BWE_TEST_LOGGING_CONTEXT_DECLARE(__bwe_log_, __PLOT__, name, \
212 static_cast<int64_t>(time), true); \
213 webrtc::testing::bwe::Logging::GetInstance()->Plot(figure, value, ssrc, \
214 alg_name); \
215 } while (0)
216
197 #define BWE_TEST_LOGGING_BAR(figure, name, value, flow_id) \ 217 #define BWE_TEST_LOGGING_BAR(figure, name, value, flow_id) \
198 do { \ 218 do { \
199 BWE_TEST_LOGGING_CONTEXT(name); \ 219 BWE_TEST_LOGGING_CONTEXT(name); \
200 webrtc::testing::bwe::Logging::GetInstance()->PlotBar(figure, name, value, \ 220 webrtc::testing::bwe::Logging::GetInstance()->PlotBar(figure, name, value, \
201 flow_id); \ 221 flow_id); \
202 } while (0) 222 } while (0)
203 223
204 #define BWE_TEST_LOGGING_BASELINEBAR(figure, name, value, flow_id) \ 224 #define BWE_TEST_LOGGING_BASELINEBAR(figure, name, value, flow_id) \
205 do { \ 225 do { \
206 BWE_TEST_LOGGING_CONTEXT(name); \ 226 BWE_TEST_LOGGING_CONTEXT(name); \
(...skipping 47 matching lines...) Expand 10 before | Expand all | Expand 10 after
254 static Logging* GetInstance(); 274 static Logging* GetInstance();
255 275
256 void SetGlobalContext(uint32_t name); 276 void SetGlobalContext(uint32_t name);
257 void SetGlobalContext(const std::string& name); 277 void SetGlobalContext(const std::string& name);
258 void SetGlobalContext(const char* name); 278 void SetGlobalContext(const char* name);
259 void SetGlobalEnable(bool enabled); 279 void SetGlobalEnable(bool enabled);
260 280
261 void Log(const char format[], ...); 281 void Log(const char format[], ...);
262 void Plot(int figure, double value); 282 void Plot(int figure, double value);
263 void Plot(int figure, double value, const std::string& alg_name); 283 void Plot(int figure, double value, const std::string& alg_name);
284 void Plot(int figure, double value, uint32_t ssrc);
285 void Plot(int figure,
286 double value,
287 uint32_t ssrc,
288 const std::string& alg_name);
264 void PlotBar(int figure, const std::string& name, double value, int flow_id); 289 void PlotBar(int figure, const std::string& name, double value, int flow_id);
265 void PlotBaselineBar(int figure, 290 void PlotBaselineBar(int figure,
266 const std::string& name, 291 const std::string& name,
267 double value, 292 double value,
268 int flow_id); 293 int flow_id);
269 void PlotErrorBar(int figure, 294 void PlotErrorBar(int figure,
270 const std::string& name, 295 const std::string& name,
271 double value, 296 double value,
272 double ylow, 297 double ylow,
273 double yhigh, 298 double yhigh,
(...skipping 40 matching lines...) Expand 10 before | Expand all | Expand 10 after
314 ThreadMap thread_map_; 339 ThreadMap thread_map_;
315 340
316 RTC_DISALLOW_COPY_AND_ASSIGN(Logging); 341 RTC_DISALLOW_COPY_AND_ASSIGN(Logging);
317 }; 342 };
318 } // namespace bwe 343 } // namespace bwe
319 } // namespace testing 344 } // namespace testing
320 } // namespace webrtc 345 } // namespace webrtc
321 346
322 #endif // BWE_TEST_LOGGING_COMPILE_TIME_ENABLE 347 #endif // BWE_TEST_LOGGING_COMPILE_TIME_ENABLE
323 #endif // WEBRTC_MODULES_REMOTE_BITRATE_ESTIMATOR_TEST_BWE_TEST_LOGGING_H_ 348 #endif // WEBRTC_MODULES_REMOTE_BITRATE_ESTIMATOR_TEST_BWE_TEST_LOGGING_H_